QUALITY CONTROL
MELT MASS-
FLOW RATE
MFR FOR
PE 100
CHANGE
OF MFR
BY PROCESSING
±20 %
LOAD TEST
TEMPERATURE
TIME NUMBER
OF TEST PIECES
5.0KG | 190 oC
10 MIN
ACCORDING TO
ISO 1133
ISO 1133:2005
CONDITION D
- Melt flow rate (MFR)
- Reference Test: ISO 1133
- Standard Value: 0.25-0.35 change in MFR
- Value caused by processing, between the measured value for material from the pipe and the measured value for the compound, must not be greater than 20%.
LONGITUDINAL
REVERSION
≤ 3%
NO EFFECT
ON SURFACE
SHAPE AND
NUMBER OF TEST
PIECES C TEST
TEMPERATURE TIMe
ACCORDING TO ISO
2505
110± 2 oC MIN
SEE ISO 2505
ISO 2505
- Longitudinal reversion (shrinkage)
- Reference Test: ISO 2505-1
- Standard value: Longitudinal reversion (shrinking) shall ≤3%
ELONGATION
AT BREAK FOR
E ≤ 12 MM
≤ 350%
TEST PIECE SHAPE
TEST SPEED
NUMBER OF
TEST PIECES
TYPE 1 a
25MM/MIN
ACCORDING TO
ISO 6259
ISO 6259-1
ISO 6259-3
- Tensile Testing
- Reference Test: ISO 6259
- Standard value: Elongation at break must be ≥350%
TEST
OXIDATION INDUCTION TIME
HYDROSTATIC STRENGTH
AT 20o / 80o
REQUIREMENT
≥ 20 MIN
NO FAILURE ON ANY TEST PIECE DURING
TEST PERIOD
TEST METHOD
TEST
ISO 1167-1
ISO 1167-2